Description
Rheem 4 Ton Packaged Heat Pump (RHPXYC048AJT000NA)
The Rheem RHPXYC048AJT000NA is an Endeavor Line Classic Plus Series packaged heat pump for homes and small buildings with 208/230 volt 1-phase service. The compressor, coils, reversing valve and indoor blower are built into one cabinet that sits on a slab or roof curb, so the only field connections are ductwork, power, a condensate drain and a thermostat.
Cooling performance
- Nominal capacity: 4 ton (45,500 BTU/h AHRI net cooling)
- Cooling efficiency: 15.2 SEER2, 11.5 EER2 (AHRI 210/240)
- Compressor: 1 scroll, 2-stage; RLA 21.5 A, LRA 102 A
- Refrigerant: R-454B, TXV, MicroChannel coils
- Sound rating: 80 dB (AHRI 270)
Heating performance
- High temperature heating (47°F): 45,500 BTU/h, COP 3.65
- Low temperature heating (17°F): 24,600 BTU/h, COP 2.32
- HSPF2: 7.2
- Defrost: Automatic defrost control; a stage of electric heat can be energized during defrost when a heater kit is installed
Airflow and cabinet
The cabinet converts between downflow (vertical) and horizontal duct connections in the field. The indoor blower is a constant-torque direct-drive multi-speed motor, so airflow can be matched to the duct system at startup.
- Nominal airflow: 1,600 CFM
- Indoor blower: 3/4 HP constant torque, direct drive multi-speed, 11x9 wheel, 1200 RPM; FLA 6.0 A
- Dimensions: 41 in H x 46-11/16 in W x 55-25/32 in L (top view); side view length 57-1/2 (see open question)
- Operating weight: 465 lb
- Shipping weight: 475 lb
- Filters: Field supplied: (2) 1x16x30 in. (optional filter kit RXRY-B02)
- Condensate drain: 3/4 in. NPT threaded PVC (external trap required)
Electrical
- Power supply: 208/230V 1-Phase, 60 Hz (187-253 V)
- Minimum circuit ampacity: 35 A
- Overcurrent protection: 50 A max overcurrent protection; min OCP 40 A
Auxiliary electric heat
Compatible Rheem heater kits approved for this exact model and voltage: RXQJ-A05J (5 kW), RXQJ-A08J (8 kW), RXQJ-B10J (10 kW), RXQJ-B15J (15 kW). Choose one in the "Add an Electric Heat Strip" option; the kit is sold separately and is not included in the base price. Unit MCA and overcurrent protection increase with the heater installed; size the supply circuit from the Rheem heater table for the kit you choose.
Warranty
Rheem residential limited warranty applies to this Endeavor Line unit; registration terms and coverage are in the Rheem warranty document for the RHPXYC series.