Description
The Goodman 2.5 Ton 16 SEER2 96% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Upflow R-32 (GLXS5BA3010 / GR9T960804CN / CAPTA3626C3) is a complete residential heating and cooling solution designed for dependable year-round comfort. This matched system combines a 2.5-ton R-32 air conditioner, 96% AFUE two-stage gas furnace, and 3-ton cased evaporator coil for energy-efficient cooling and high-efficiency heating.
Designed for upflow installation, the system draws return air through the bottom and supplies conditioned air from the top. The furnace features two-stage heating and a multi-speed ECM blower motor, helping provide consistent airflow, improved temperature control, and efficient operation.
Key Features
- 2.5 Ton Cooling Capacity – Delivers 30,000 BTU of residential cooling
- 16 SEER2 Efficiency – Supports energy-efficient cooling performance
- 80,000 BTU Gas Furnace – Provides dependable two-stage heating
- 96% AFUE Efficiency – Converts approximately 96% of fuel into usable heat
- Upflow R-32 Configuration – Suitable for basements, closets, utility rooms, and mechanical rooms
- Multi-Speed ECM Blower – Promotes consistent airflow and efficient operation
- 3 Ton Evaporator Coil – Supports the matched system’s airflow and efficiency requirements
System Components Included
- Goodman GLXS5BA3010 2.5 Ton 16 SEER2 R-32 Air Conditioner
- Goodman GR9T960804CN 80,000 BTU 96% AFUE Two-Stage Gas Furnace
- Goodman CAPTA3626C3 3 Ton Cased Upflow/Downflow R-32 Evaporator Coil
Compatibility & Installation Notes
The GLXS5BA3010 / GR9T960804CN / CAPTA3626C3 system is designed for residential upflow applications. Although the evaporator coil has a nominal 3-ton capacity, it may be paired with the 2.5-ton condenser as part of an approved matched configuration. The complete combination should be verified using applicable AHRI certification data.
Compatibility with the property’s ductwork, electrical service, natural gas supply, refrigerant lines, condensate drainage, and approved high-efficiency furnace venting must be confirmed before installation.
Specifications
- System Type: Gas Electric Split System
- Cooling Capacity: 2.5 Ton / 30,000 BTU
- Evaporator Coil Capacity: 3 Ton / 36,000 BTU nominal
- Heating Input: 80,000 BTU
- Heating Output: Approximately 76,800 BTU
- Cooling Efficiency: 16 SEER2
- Furnace Efficiency: 96% AFUE
- Furnace Stages: Two-Stage
- Blower Motor: Multi-Speed ECM
- Refrigerant: R-32
- Installation Orientation: Upflow
Installation Notes
- Verify compatibility with the existing upflow ductwork
- Confirm electrical service and natural gas connection requirements
- Check the required refrigerant line sizes before installation
- Install approved high-efficiency furnace venting
- Provide proper drainage for both the condensing furnace and evaporator coil
- Use a compatible two-stage thermostat to access full staging functionality
- Confirm adequate installation and service clearances
- Verify the complete system’s AHRI-rated performance
- Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What is included in this Goodman HVAC system?
The package includes the GLXS5BA3010 air conditioner, GR9T960804CN gas furnace, and CAPTA3626C3 cased evaporator coil.
What is the cooling capacity of this system?
The system provides 2.5 tons or 30,000 BTU of cooling capacity.
Is the furnace single-stage or two-stage?
The Goodman GR9T960804CN is a two-stage gas furnace, allowing it to operate at a lower heating level during mild conditions and increase its output when additional heat is required.
Does this system require a two-stage thermostat?
A compatible two-stage thermostat is recommended to provide proper control over both furnace heating stages.
What is the approximate heating output?
With a 96% AFUE rating, the 80,000 BTU furnace provides approximately 76,800 BTU of usable heating output.
Why is a 3-ton evaporator coil paired with a 2.5-ton air conditioner?
A larger nominal coil may be used to achieve the system’s targeted efficiency and airflow performance. The exact combination should be confirmed using applicable AHRI certification data.
Does this condensing furnace require drainage?
Yes. A 96% AFUE condensing furnace produces condensate and requires an approved drainage system in addition to the evaporator coil drain.
Does this system use R-32 refrigerant?
Yes. The air conditioner and evaporator coil are designed for R-32 refrigerant.
Videos
-
Goodman Air Conditioning and Heating - Built In America | HVAC365
In this episode of HVAC365, we take a closer look at Goodman, ...
-
Goodman Manufacturing's Headquarters An Exclusive Look Inside | Military Makeover with Montel
Join us for an exclusive tour inside Goodman Manufacturing's h...
-
Inside the Goodman Brand: A Comprehensive Tour of HVAC Excellence | HVAC365
Step into the world of HVAC excellence with an immersive journ...
-
Operation Comfort: Installing a Goodman HVAC System for a Veteran's Home Makeover | HVAC365
"Operation Comfort" showcases the transformation of a veteran'...
-
Maximizing Comfort: A Goodman Heating and Cooling System Installation | HVAC365
In this episode of HVAC365, join us as we delve into the insta...