Description
Product Summary
The Goodman GXV9SA2410 is a 2-ton GXV9S Series variable-speed inverter air conditioner condenser for R-32 split systems, rated up to 23,200 BTU/h of cooling. The series reaches up to 19 SEER2 with matched indoor equipment.
An inverter-driven swing compressor modulates capacity to match the load, and the unit runs on 208/230V single-phase power (MCA 22.4 A, MOP 25 A). Goodman lists the AHVE36CP1300 variable-speed air handler as a match.
Key Features
- Inverter compressor: variable-speed capacity for steady temperatures and humidity control.
- Up to 19 SEER2: high-efficiency cooling with matched components.
- R-32 refrigerant: lower-GWP refrigerant.
- Hurricane rated: meets 2023 Florida Building Code unit integrity requirements when properly anchored.
- Matched systems: pairs with Goodman AHVE air handlers and R-32 coils.
- 10-year unit replacement: and 10-year parts limited warranties with registration.
Specifications
| Brand | Goodman |
|---|---|
| Model | GXV9SA2410 |
| Series | GXV9S |
| Nominal Capacity | 2 tons |
| Max Cooling (AHRI rated) | 23,200 BTU/h |
| Efficiency | Up to 19 SEER2 (series, system dependent) |
| Compressor | Variable-speed inverter swing compressor |
| Refrigerant | R-32 |
| Electrical | 208-230V / 1-Phase / 60 Hz |
| MCA | 22.4 A |
| MOP | 25 A |
| Equipment Weight | 129 lb |
| Shipping Weight | 143 lb |
| Matching Indoor Unit (listed) | AHVE36CP1300 |
| Listings | AHRI Certified, ETL Listed |
Ideal Applications
- Residential central AC replacements
- High-efficiency new construction
- Coastal and hurricane-zone homes (with anchor kit)
- Rebate-eligible system upgrades
Frequently Asked Questions
What indoor unit should I pair it with?
Goodman lists the AHVE36CP1300 as a matched air handler. Use AHRI matchups to confirm ratings.
Is it a heat pump?
No. This is a cooling-only air conditioner condenser.
What refrigerant does it use?
R-32.
What breaker size is needed?
Maximum overcurrent protection is 25 A with an MCA of 22.4 A.