Description
The Goodman 3.5 Ton 15.2 SEER2 92% AFUE 80,000 BTU Gas Electric Air Conditioner Split System Upflow with R-32 Refrigerant (GLXS4BA4210-GR9S920805CN-CAPTA4230C3) is a matched residential HVAC system designed to provide efficient cooling and dependable gas heating for year-round indoor comfort. This configuration combines the GLXS4BA4210 air conditioner condenser, GR9S920805CN high-efficiency gas furnace, and CAPTA4230C3 cased evaporator coil for an upflow residential installation.
With a nominal 3.5 ton / 42,000 BTU cooling capacity, 15.2 SEER2 cooling efficiency, and an 80,000 BTU furnace rated at 92% AFUE, this Goodman system balances cooling efficiency with efficient gas heating performance. The cooling circuit uses R-32 lower-GWP refrigerant, while the upflow configuration is suitable for applications where conditioned air is supplied upward into the home's duct system.
Key Features
- 3.5 Ton Cooling Capacity – Provides approximately 42,000 BTU of nominal cooling capacity
- 15.2 SEER2 Efficiency – Offers efficient seasonal cooling performance for this matched configuration
- 80,000 BTU Gas Furnace – Delivers dependable heating capacity for residential applications
- 92% AFUE Rating – High-efficiency furnace helps convert more fuel energy into usable indoor heat
- Single-Stage Gas Furnace – GR9S series furnace provides straightforward and dependable heating operation
- R-32 Refrigerant – Cooling circuit uses modern lower-GWP R-32 refrigerant
- Upflow Configuration – Designed for applications where conditioned air is distributed upward
- Gas Electric Operation – Combines electric air conditioning with gas furnace heating
Product Specifications
- Brand: Goodman
- System Model: GLXS4BA4210-GR9S920805CN-CAPTA4230C3
- Outdoor Condenser Model: GLXS4BA4210
- Gas Furnace Model: GR9S920805CN
- Evaporator Coil Model: CAPTA4230C3
- Product Type: Gas Electric Air Conditioner Split System
- Nominal Cooling Capacity: 3.5 Ton
- Heating Efficiency: 92% AFUE
- Furnace Operation: Single-Stage
- System Configuration: Upflow
- Refrigerant: R-32
- Refrigerant Classification: A2L
Benefits
- Provides both cooling and gas heating in one matched HVAC configuration
- 15.2 SEER2 rating supports efficient seasonal cooling
- 92% AFUE furnace offers improved fuel utilization compared with standard 80% AFUE models
- 80,000 BTU furnace provides dependable residential heating capacity
- Uses modern lower-GWP R-32 refrigerant in the cooling circuit
- Upflow design accommodates common residential duct configurations
- Matched Goodman components simplify equipment selection
- Suitable for new installations and compatible HVAC replacement projects
- Designed to provide reliable year-round indoor comfort
Compatibility & Installation
The Goodman GLXS4BA4210-GR9S920805CN-CAPTA4230C3 package includes the outdoor condenser, gas furnace, and cased evaporator coil for an upflow gas/electric split-system installation. Proper equipment sizing, airflow, refrigerant setup, and professional installation are necessary to achieve the listed performance.
Installation considerations:
- Verify that 3.5-ton cooling capacity matches the home's calculated cooling load
- Confirm that the 80,000 BTU furnace is appropriately sized for the heating load
- Ensure the installation requires an upflow airflow configuration
- Confirm proper duct sizing and system airflow
- Provide appropriate gas supply and combustion air
- Follow required venting guidelines for the 92% AFUE condensing furnace
- Provide proper furnace and evaporator coil condensate drainage
- Follow R-32 A2L refrigerant handling and installation requirements
- Verify electrical requirements and required service clearances
- Follow Goodman instructions and applicable local HVAC codes
- Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What cooling capacity does this Goodman system provide?
It provides a nominal 3.5 tons of cooling, equivalent to approximately 42,000 BTU.
What is the cooling efficiency of this system?
This matched configuration is listed at 15.2 SEER2.
What is the furnace capacity and efficiency?
The GR9S920805CN provides 80,000 BTU input capacity and is rated at 92% AFUE.
Is the furnace single-stage or two-stage?
The GR9S920805CN is a single-stage gas furnace, designed for dependable residential heating operation.
What refrigerant does this system use?
The air-conditioning circuit uses R-32, a lower-GWP A2L refrigerant used in newer HVAC systems.
What installation orientation is this system designed for?
This package is configured for upflow installation, where conditioned air moves upward into the supply ductwork.
Videos
-
Goodman Air Conditioning and Heating - Built In America | HVAC365
In this episode of HVAC365, we take a closer look at Goodman, ...
-
Goodman Manufacturing's Headquarters An Exclusive Look Inside | Military Makeover with Montel
Join us for an exclusive tour inside Goodman Manufacturing's h...
-
Inside the Goodman Brand: A Comprehensive Tour of HVAC Excellence | HVAC365
Step into the world of HVAC excellence with an immersive journ...
-
Operation Comfort: Installing a Goodman HVAC System for a Veteran's Home Makeover | HVAC365
"Operation Comfort" showcases the transformation of a veteran'...
-
Maximizing Comfort: A Goodman Heating and Cooling System Installation | HVAC365
In this episode of HVAC365, join us as we delve into the insta...