Description
The Goodman 3 Ton 15 SEER2 92% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow R-32 (GLXS5BA3610 / GR9S921004CN / CAPTA3626C3) is a complete residential heating and cooling solution designed for dependable year-round comfort. This matched system combines a 3-ton R-32 air conditioner, 92% AFUE high-efficiency gas furnace, and 3-ton cased evaporator coil for efficient cooling and reliable heating.
Designed for upflow installation, the system features a single-stage gas furnace and a multi-speed ECM blower motor for consistent airflow and efficient operation. In an upflow configuration, return air enters through the bottom of the furnace, while conditioned air exits through the top.
Key Features
- 3 Ton Cooling Capacity – Delivers 36,000 BTU of residential cooling
- 15 SEER2 Efficiency – Supports energy-efficient cooling performance
- 100,000 BTU Gas Furnace – Provides dependable single-stage heating
- 92% AFUE Efficiency – Converts approximately 92% of fuel into usable heat
- Multi-Speed ECM Blower – Promotes consistent airflow and efficient operation
- Upflow R-32 System – Designed for vertical applications with upward supply airflow
- Matched 3 Ton Coil – Supports the system’s cooling capacity and performance
System Components Included
- Goodman GLXS5BA3610 3 Ton 15 SEER2 R-32 Air Conditioner
- Goodman GR9S921004CN 100,000 BTU 92% AFUE Single-Stage Gas Furnace
- Goodman CAPTA3626C3 3 Ton Cased Upflow/Downflow R-32 Evaporator Coil
Compatibility & Installation Notes
The GLXS5BA3610 / GR9S921004CN / CAPTA3626C3 system is designed for residential upflow applications. Compatibility with the property’s ductwork, electrical service, natural gas supply, refrigerant lines, condensate drainage, thermostat, and high-efficiency furnace venting must be confirmed before installation.
As a high-efficiency condensing furnace, the GR9S921004CN requires approved venting and proper condensate drainage. The complete equipment combination should also be verified using applicable manufacturer documentation and AHRI certification.
Because this system includes a 100,000 BTU furnace, a professional heating-load calculation is recommended to ensure the furnace is appropriately sized for the property.
Specifications
- System Type: Gas Electric Split System
- Cooling Capacity: 3 Ton / 36,000 BTU
- Evaporator Coil Capacity: 3 Ton
- Heating Input: 100,000 BTU
- Heating Output: Approximately 92,000 BTU
- Cooling Efficiency: 15 SEER2
- Furnace Efficiency: 92% AFUE
- Furnace Stages: Single-Stage
- Blower Motor: Multi-Speed ECM
- Refrigerant: R-32
- Installation Orientation: Upflow
Installation Notes
- Verify compatibility with the existing upflow ductwork
- Confirm electrical service and natural gas connection requirements
- Check the required refrigerant line sizes before installation
- Install approved high-efficiency furnace venting
- Provide proper furnace and evaporator-coil condensate drainage
- Perform a heating-load calculation to confirm appropriate furnace sizing
- Confirm the complete matched-system efficiency through AHRI documentation
- Installation should be completed by a qualified HVAC professional
Frequently Asked Questions
What is included in this Goodman HVAC system?
The package includes the GLXS5BA3610 air conditioner, GR9S921004CN gas furnace, and CAPTA3626C3 cased evaporator coil.
What is the cooling capacity of this system?
The system provides 3 tons or 36,000 BTU of cooling capacity.
Is the furnace single-stage or two-stage?
The Goodman GR9S921004CN is a single-stage gas furnace that provides consistent heating output.
What does 92% AFUE mean?
It means approximately 92% of the furnace’s fuel is converted into usable heating energy, providing an estimated heating output of 92,000 BTU.
Does this furnace require condensate drainage?
Yes. Because it is a high-efficiency condensing furnace, it requires proper furnace condensate drainage in addition to drainage for the evaporator coil.
What does upflow installation mean?
In an upflow installation, return air enters through the bottom of the furnace and heated or cooled air exits through the top.
Does this system use R-32 refrigerant?
Yes. The air conditioner and evaporator coil are designed for R-32 refrigerant.
Videos
-
Goodman Air Conditioning and Heating - Built In America | HVAC365
In this episode of HVAC365, we take a closer look at Goodman, ...
-
Goodman Manufacturing's Headquarters An Exclusive Look Inside | Military Makeover with Montel
Join us for an exclusive tour inside Goodman Manufacturing's h...
-
Inside the Goodman Brand: A Comprehensive Tour of HVAC Excellence | HVAC365
Step into the world of HVAC excellence with an immersive journ...
-
Operation Comfort: Installing a Goodman HVAC System for a Veteran's Home Makeover | HVAC365
"Operation Comfort" showcases the transformation of a veteran'...
-
Maximizing Comfort: A Goodman Heating and Cooling System Installation | HVAC365
In this episode of HVAC365, join us as we delve into the insta...