Goodman 5 Ton -16 SEER2 80% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow R-32 | GLXS5BA6010 GR9S801005CX CAPTA6030C3

Goodman

5 Star RatingLeave a review
No reviews yet Write a Review
SKU:
GLXS5BA6010-GR9S801005CX-CAPTA6030C3
Your Price $0.00

Detecting ZIP...
Est. Net Incentive Amount: $0.00
We could not detect your ZIP automatically. Enter your ZIP to check incentives.
Available Incentives
$0.00
Selected Incentives
0
Unpriced Programs
0
Estimates assume eligibility; programs and amounts can change.
Condition:
New
Width:
48.00 (in)
Height:
48.00 (in)
Depth:
40.00 (in)

Questions about Goodman 5 Ton -16 SEER2 80% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow R-32 | GLXS5BA6010 GR9S801005CX CAPTA6030C3?

Contact us for advice or additional information; our product specialists are here to help!

SupplierGateway® Certified i
Minority-Owned • Small Business

Fast Shipping

Customer Support

Warranty Coverage

Financing Available

$6,781.00

45 in stock • Ships in 2-3 Business Days
Overview

Goodman 5 Ton -16 SEER2 80% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow R-32 | GLXS5BA6010 GR9S801005CX CAPTA6030C3

Goodman 5 Ton -16 SEER2 80% AFUE 100,000 BTU Gas Electric Air Conditioner Split System Upflow R-32, model GLXS5BA6010 GR9S801005CX CAPTA6030C3 - view 5
Product details

Description

The Goodman GLXS5BA6010-GR9S801005CX-CAPTA6030C3 is a 5-ton, 16-SEER2 gas/electric split system that handles both heating and cooling in a single matched bundle — the condenser, 80% AFUE 100,000 BTU gas furnace, and upflow cased coil arrive together, AHRI-certified as a system, so there's no guesswork about whether the components match. Homeowners and contractors dealing with larger square footages have historically had to cobble together separate components and hope the ratings held up at install; this bundle ships pre-matched and certified. Running on R-32 refrigerant with a 16-SEER2 efficiency rating and an EER of 11.7, it delivers real operating cost savings over older R-410A systems while meeting current refrigerant transition standards — available nationwide except California.

Key Features

  • AHRI-Certified System Match: The condenser, furnace, and coil are certified together as a system, so the 16-SEER2 rating is guaranteed — not an estimate based on mixing components.
  • 16-SEER2 / 11.7 EER Efficiency: At 5 tons and 16 SEER2, this system cuts cooling energy use significantly compared to the 14-SEER2 minimum, which shows up directly on utility bills over a long cooling season.
  • R-32 Refrigerant: R-32 has a lower global warming potential than R-410A and is the forward-facing refrigerant for residential systems, positioning this install ahead of coming regulatory shifts.
  • 80% AFUE, 100,000 BTU Gas Furnace: The included GR9S801005CX furnace delivers 100,000 BTU of heating capacity at 80% efficiency — enough output for large homes in cold climates without stepping up to a pricier high-efficiency unit.
  • Upflow Configuration: The upflow setup works with the most common residential duct layouts — supply air exits the top of the furnace and feeds directly into overhead duct systems without any conversion.
  • Solder Line Set Connections, 3/8" Liquid Line: The 3/8-inch OD liquid line connection and solder-type fittings give a clean, leak-resistant joint that holds up better over time than flare connections in high-vibration environments.

Is this the right unit for your project?

A 5-ton system is generally sized for homes in the 2,200–3,000 square foot range, but that rule of thumb shifts significantly with ceiling height, insulation grade, window area, local climate, and duct condition — a Manual J load calculation confirms the right size for the specific structure. Undersizing a 5-ton in a smaller home means short cycling, excess humidity, and compressor wear. Oversizing in a house that only needs 3 or 4 tons causes the same short-cycling problems and drives up install cost unnecessarily. This system is a strong fit for larger single-family homes in hot-summer, cold-winter climates where both the 100,000 BTU heating capacity and the 5-ton cooling output get used hard every year.

Split system bundle vs. buying components separately

Buying a condenser, furnace, and coil as a pre-matched AHRI-certified bundle like the GLXS5BA6010-GR9S801005CX-CAPTA6030C3 has one clear advantage over assembling parts individually: the efficiency rating is certified at the system level, not extrapolated. When you mix-and-match a condenser from one brand with a coil from another, the published SEER2 may not hold — AHRI certification requires the exact combination to be tested together. The tradeoff is flexibility; a bundle locks you into the matched components. For most 5-ton replacement jobs where the existing system is being fully swapped out, the bundle approach saves time sourcing parts, reduces compatibility risk, and locks in the certified rating.

Where it fits best

  • Full system replacement in larger single-family homes (roughly 2,200–3,000 sq ft depending on climate and insulation)
  • New construction where the mechanical room is designed for upflow gas furnace configuration
  • Homes in cold-winter, hot-summer climates needing strong heating and cooling output from a single system
  • Installations where contractors want an AHRI-certified matched set to document efficiency ratings for permits or rebates
  • Regions outside California where R-32 systems are approved and current refrigerant rules apply

Why R-32 matters for this install

R-410A has been the residential standard refrigerant for two decades, but EPA phasedown rules are pushing the industry toward lower-GWP alternatives. R-32 has roughly one-third the global warming potential of R-410A and is one of the primary replacements the industry has aligned on. For the person buying this system today, it means the refrigerant won't be subject to the same supply restrictions and cost spikes that R-22 and R-410A faced as their phasedowns accelerated. Recovery equipment and handling procedures for R-32 differ from R-410A — verify the equipment on hand is rated for R-32 before starting the job.

Installation & what else you’ll need

To complete this installation, you'll need a compatible thermostat rated for gas/electric split systems — a programmable or smart thermostat with both heating and cooling control stages works with this setup. The outdoor condenser needs a level concrete pad or equipment stand rated for the unit's weight and footprint; check the installation manual for the exact dimensions before pouring or ordering. Line set runs between the condenser and the indoor coil require a 3/8-inch OD liquid line and an appropriately sized suction line; connections are solder-type, so the line set and fittings must be compatible with that method. A properly sized disconnect box and whip (flex conduit with wiring) are required at the condenser. On the furnace side, plan for a gas supply line with shutoff, a flue venting path that meets local code for an 80% AFUE non-condensing furnace (B-vent), and a 115V electrical connection for the furnace controls separate from the 240V supply to the condenser. The upflow coil (CAPTA6030C3) mounts above the furnace in the supply plenum; confirm your existing plenum or plan a new duct transition that matches the coil's outlet dimensions. A condensate drain line is required from the coil drain pan — route it to an approved drain point. Note that this system is not approved for sale or installation in California.

Frequently Asked Questions

How many tons is the Goodman GLXS5BA6010-GR9S801005CX-CAPTA6030C3?

The GLXS5BA6010-GR9S801005CX-CAPTA6030C3 is a 5-ton system. That's 60,000 BTU of cooling capacity from the condenser matched with a 100,000 BTU gas furnace for heating. It's sized for larger homes, generally in the 2,200–3,000 square foot range depending on climate and insulation, with a Manual J confirming the right fit.

What SEER2 rating does this Goodman 5-ton gas electric split system have?

This Goodman bundle is rated at 16 SEER2 and 11.7 EER as an AHRI-certified matched system. The 16-SEER2 rating applies specifically to this condenser, furnace, and coil combination — not to the condenser alone. Using different components would require a separate AHRI certification to confirm the efficiency rating holds.

What refrigerant does the Goodman GLXS5BA6010 condenser use?

The GLXS5BA6010 condenser uses R-32 refrigerant. R-32 has a lower global warming potential than R-410A and is one of the primary refrigerants the industry has moved to as R-410A production faces EPA phasedown restrictions. Recovery and handling equipment must be rated for R-32 — it's not interchangeable with R-410A tools.

What size line set do I need for this Goodman 5-ton split system?

The liquid line connection on this system is 3/8-inch OD, and connections are solder-type. The suction line size should match the specification in the installation manual for a 5-ton system. Line sets must be compatible with R-32 refrigerant and rated for the operating pressures of this equipment.

Is this Goodman gas electric split system available in California?

No — the GLXS5BA6010-GR9S801005CX-CAPTA6030C3 is available nationwide except California. California has specific refrigerant and efficiency regulations that this system does not currently meet for sale in that state. Buyers in all other U.S. states can purchase and install it.

Does this Goodman 5-ton split system come with the coil and furnace included?

Yes. The GLXS5BA6010-GR9S801005CX-CAPTA6030C3 is a three-component bundle: the GLXS5BA6010 outdoor condenser, the GR9S801005CX 80% AFUE 100,000 BTU upflow gas furnace, and the CAPTA6030C3 cased upflow coil. All three are AHRI-certified together, so the 16-SEER2 efficiency rating is confirmed for this exact combination.

White Paper

Comfort for the people who live there

The right equipment keeps the rooms you live in steady and quiet, whether it's dinner in the kitchen or a weekend project in the garage.

Specifications

Extra Information

Find your comfort-ready size with confidence

Get a fast, learning-friendly estimate for tons and BTUs, then review it with a Pro to dial in the perfect fit for your home.

Brand:
Goodman
Width:
48.00 (in)
Height:
48.00 (in)
Depth:
40.00 (in)
Weight:
557.00 LBS
Safety Information:
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
EER:
11.7
Configuration:
Upflow
Capacity (Tons):
5
Product Category:
Gas Heating & Air Conditioner Bundle
AHRI Certified:
Yes
Liquid Line Size:
3/8 in
SEER2:
16 SEER2
Line Set Connection Type:
Braze
Refrigerant Type:
R-32
Prop 65 Warning:
Yes
Unit Weight:
218.5 lb
Heating Stages:
Single Stage
Heating Input (BTU):
100,000 - 149,000 BTU
Shipping Weight:
233.5 lb
Vent Type:
Chimney / Category I
AFUE:
80%
AHRI Reference Number:
215381108
Airflow (CFM):
2,000
EER2:
11 EER2
Blower Motor Type:
ECM Constant Torque
Electrical Frequency:
60 Hz
Electrical Phase:
1-Phase
Cabinet Width (in):
21
Color:
Gray
Cooling Capacity (BTU):
60,000
DOE Regional Compliance:
Nationwide
Compressor Stages:
Two Stage
Voltage / Phase:
208/230V 1-Phase
Condenser GLXS5BA6010 - Nominal Capacity (Tons):
5
Condenser GLXS5BA6010 - Cooling Capacity (BTU/h):
60,000
Condenser GLXS5BA6010 - Refrigerant:
R-32
Condenser GLXS5BA6010 - Voltage/Phase/Hz:
208-230 V / 1 Ph / 60 Hz
Condenser GLXS5BA6010 - Minimum Circuit Ampacity (MCA):
36.4 A
Condenser GLXS5BA6010 - Maximum Overcurrent Protection (MOP):
60 A
Condenser GLXS5BA6010 - Compressor Type:
Scroll
Condenser GLXS5BA6010 - Compressor Stages:
Two Stage
Condenser GLXS5BA6010 - Liquid Line Size:
3/8 in
Condenser GLXS5BA6010 - Suction Line Size:
1-1/8 in
Condenser GLXS5BA6010 - Sound Level (dB):
76
Condenser GLXS5BA6010 - Unit Dimensions (W x D x H):
35.5 in x 35.5 in x 36.5 in
Condenser GLXS5BA6010 - Unit Weight:
249 lb
Condenser GLXS5BA6010 - Shipping Weight:
309 lb
Furnace GR9S801005CX - Input (BTU/h):
100,000
Furnace GR9S801005CX - Output (BTU/h):
80,000
Furnace GR9S801005CX - AFUE:
80%
Furnace GR9S801005CX - Heating Stages:
Single Stage
Furnace GR9S801005CX - Blower Motor Type:
ECM Constant Torque
Furnace GR9S801005CX - Maximum Cooling Capacity (Tons):
5
Furnace GR9S801005CX - Configuration:
Upflow/Horizontal
Furnace GR9S801005CX - Cabinet Width:
21 in
Furnace GR9S801005CX - Vent Type:
Chimney / Category I
Furnace GR9S801005CX - Gas Type:
Propane Convertible
Furnace GR9S801005CX - Voltage/Phase/Hz:
115 V / 1 Ph / 60 Hz
Furnace GR9S801005CX - Unit Dimensions (W x D x H):
24.5 in x 28 in x 33.375 in
Furnace GR9S801005CX - Shipping Weight:
132 lb
Evaporator Coil CAPTA6030C3 - Nominal Capacity (Tons):
5
Evaporator Coil CAPTA6030C3 - Cased/Uncased:
Cased
Evaporator Coil CAPTA6030C3 - Configuration:
Upflow/Downflow
Evaporator Coil CAPTA6030C3 - Cabinet Width:
21 in
Evaporator Coil CAPTA6030C3 - Metering Device:
TXV
Evaporator Coil CAPTA6030C3 - Refrigerant:
R-32
Evaporator Coil CAPTA6030C3 - Liquid Line Size:
3/8 in
Evaporator Coil CAPTA6030C3 - Suction Line Size:
7/8 in
Please Note: To validate the manufacturer's warranty, equipment must be installed by a qualified licensed professional in accordance with local codes and the manufacturer's installation requirements.

2023 Energy Standards

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Department of Energy (DOE) State Regulations – Effective 2023

Click the link below to view the energy standards applicable to your region.

DOE State Standards Document

Documents & warranty
Warranty
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Videos5 videos
Goodman Air Conditioning & Heating: Built in America
Frequently asked questions
What size is the ?
The is a 5 ton unit.
What is the SEER2 rating of the ?
The is rated at 16 SEER2 SEER2.
What refrigerant does the use?
It uses R-32 refrigerant.
What is the heating input of the ?
The heating input is 100,000 - 149,000 BTU BTU.
What is the AFUE of the ?
The is rated at 80% AFUE.
Is the AHRI certified?
Yes. The AHRI reference number is 215381108.
How much cooling does the provide?
It is rated for 60,000 BTU of cooling.
What power supply does the need?
It requires 208/230V 1-Phase power.
What warranty comes with the GLXS5BA6010-GR9S801005CX-CAPTA6030C3?
10 Years Heat Exchanger & 10 Years Compressor & 10 Years Parts | Registration Required within 60 Days of Purchase
Who makes the GLXS5BA6010-GR9S801005CX-CAPTA6030C3?
The GLXS5BA6010-GR9S801005CX-CAPTA6030C3 is made by Goodman.