Description
Rheem 12.5 Ton Commercial Gas/Electric Package Unit (RGEDYB150ADG152AABA0)
The Rheem RGEDYB150ADG152AABA0 is a Commercial Classic Series packaged gas/electric rooftop unit in Rheem's medium commercial (7.5-12.5 ton) cabinet. It combines R-454B air conditioning and a 150,000 BTU/h two-stage natural gas furnace in one cabinet, for buildings with 460 volt 3-phase service and gas on the roof: retail, offices, restaurants, schools, churches and light industrial space.
Factory options on this SKU: factory louvered coil guards that protect the outdoor coil from hail and debris.
Cooling performance
- Nominal capacity: 12.5 ton (142,000 BTU/h AHRI net cooling)
- Efficiency: 10.8 EER, 14 IEER (AHRI 340/360)
- Compressor: 2 (tandem) scroll; RLA 8.8 each, LRA 74.6 each; 2 stages of cooling
- Refrigerant: R-454B (A2L), factory charged, with a factory-installed refrigerant leak detection sensor
- Metering: TXV
- Sound rating: 87 dB (AHRI 270)
Gas heating
- Heating input: 150,000 2nd stage / 105,000 1st stage BTU/h
- Heating output: 121,500 2nd stage / 85,050 1st stage BTU/h
- Efficiency: 81% steady-state efficiency
- Gas valve: Two-stage, 6 burners
- Heat exchanger: Aluminized steel tubular, min. 20-ga steel with 1.2 mil aluminum-silicone coating
- Temperature rise: 5-35°F low fire / 15-45°F high fire
- Fuel: Natural gas as shipped. LP conversion kit RXGJ-FP39 (field-installed)
Airflow and cabinet
The cabinet converts between downflow (vertical) and horizontal duct connections in the field. The indoor blower is an adjustable belt drive with a variable frequency drive (VFD) for medium static, so airflow can be matched to the ductwork at startup.
- Nominal airflow: 5,000 CFM
- Indoor blower: 5 HP (frame 184, 1725 RPM), FLA 6.3
- Dimensions: 60 in H x 59-1/2 in W x 90-1/8 in D (base rail); cabinet top 57-7/8 x 89
- Operating weight: 1089 lb
- Shipping weight: 1128 lb
- Filters: (4) 2x20x25 in. disposable, furnished
- Controls: CoreCommand (non-communicating)
Electrical
- Power supply: 460V 3-Phase, 60 Hz (operating range 414-506 V)
- Minimum circuit ampacity: 31 A (34 A with power exhaust)
- Overcurrent protection: 35 A max overcurrent protection (40 A with power exhaust); min OCP 35 A (40 A with PE)
Accessories
Rheem field accessories for this cabinet include economizers, fresh air dampers, power exhaust and roof curbs (RXKG-DDD14, RXKG-DDD24, RXKG-SD14, RXKG-SD24, RXRD-01MDDBM3, RXRD-01MDHBM3, RXRD-11MDDAM3, RXRD-11MDHAM3, RXRD-31MDDAM3, RXRD-41MDDAM3, RXRD-41MDHAM3, RXRD-51MDDAM3, RXRD-51MDHAM3, RXRF-ADA1, RXRF-ADB1, RXRF-ADC1, RXRX-CDF01D, RXRX-DDCAE, RXRX-RDF01D, RXRX-RDF03D). Match accessories by cabinet and airflow direction; see Rooftop Unit Accessories.
Warranty
Rheem limited warranty for commercial applications: 5-year compressor and 1-year parts, with a 10-year limited warranty on the heat exchanger. Full terms are in the Rheem warranty document for this series.
White Paper
- Rheem RGEDYB Spec Sheet (Part 1)
- Rheem RGEDYB Spec Sheet (Part 2)
- Rheem RGEDYB Spec Sheet (Part 3)
- Rheem RGEDYB Spec Sheet (Part 4)
- Rheem RGEDYB Spec Sheet (Part 5)
- Rheem RGEDYB Spec Sheet (Part 6)
- Rheem RGEDYB Spec Sheet (Part 7)
- Rheem RGEDYB Installation Manual (Part 1)
- Rheem RGEDYB Installation Manual (Part 2)
- Rheem RGEDYB Installation Manual (Part 3)
- Rheem RGEDYB Installation Manual (Part 4)
- Rheem RGEDYB Installation Manual (Part 5)
- Rheem RGEDYB Installation Manual (Part 6)
- Rheem RGEDYB Installation Manual (Part 7)
- Rheem RGEDYB Installation Manual (Part 8)
- Rheem RGEDYB Installation Manual (Part 9)
- Rheem RGEDYB Installation Manual (Part 10)
- Rheem RGEDYB Installation Manual (Part 11)